topbar.section2.text
topbar.section3.text

Monitoring / Security / Optimisation

Power optimiser S500B-1GM4MRM SolarEdge

Manufacturer: SolarEdge

INDEX: S500B-1GM4MRM

Product number: S500B-1GM4MRM
Product information "Power optimiser S500B-1GM4MRM SolarEdge"

The SolarEdge S500B Power Optimiser helps to increase the energy production of each module in your PV installation.

It has been specifically designed to work with SolarEdge inverters and provides a unique solution to prevent problems with module mismatch or partial shading. It detects unnatural connector behaviour, preventing potential hazards. Reduces the voltage of each module during installation or in case of fire.

  • Up to 25% more energy
  • High level of efficiency of 99.5%
  • Quick installation with a single screw
  • Separate monitoring for each module allows easier system management
  • Reduces the voltage of each module - at installation or in case of fire.
  • System design maximises space utilisation for higher yields.
  • The technology used prevents problems in case of module mismatch or partial shading.

Cable length:

  • input wires 0.1 m
  • output wires 2,3 m (+) and 0,1 m (-)
General features:
Application: Optymalizacja
Dimensions WxHxD [mm]: 129 x 155 x 45
Supported number of PV modules: 1
Weight [kg]: 0.66
Dimensions [mm]: 129.0 x 155.0 x 45.0
Electrical characteristics:
Maximum short-circuit current per MPPT [A]: 15
Number of optimisers per chain: -
Power [W]: 500
Max. voltage [V]: 125
Min. MPPT voltage [V]: 12.5
Max. MPPT voltage [V]: 105
Efficeincy:
Euro efficiency [%]: 98.6
Max. efficiency [%]: 99.5
Solaredge:
Chain length - HD-WAVE and single phase inverter / number of optimisers and PV modules: 6 - 25
Chain length - three-phase inverter / number of optimisers and PV modules: 14 - 50
Chain length - three-phase inverter for 277/480 V grid / number of optimisers and PV modules: -
Chain length - three-phase inverter from 15 kW / number of PV modules: -
Chain length - three-phase inverter from 15 kW / number of optimisers: -
Chain length of PV modules - three-phase inverter from 16 kW [pcs].: -
Chain length of PV modules - three-phase inverter from 25 kW [pcs].: -
Chain length of power optimisers - three-phase inverter from 16 kW and above [pcs].: -
Chain length of power optimisers - three-phase inverter from 25 kW [pcs.]: -
Maximum Power per String - inverter HD-WAVE [W]: 5700
Maximum Power per String - inverter three phase [W]: 11250
MaximumStringLengthInverterHDWaveAndSinglePhaseNumberOfOptimizersAndPVModules: 25
MaximumStringLengthInverterThreePhaseNumberOfOptimizersAndPVModules: 50
MinimumStringLengthInverterHDWaveAndSinglePhaseNumberOfOptimizersAndPVModules: 6
MinimumStringLengthInverterThreePhaseNumberOfOptimizersAndPVmodules: 14